Skip to main content

Airbyte Cloud ExecModule

Overview​

AirbyteCloudModule reads Airbyte Cloud connections and jobs. Use it to find the connection that delivers data to your warehouse, review its sync history, or check the exact job tied to a downstream handoff. A workflow can use the returned job status to proceed after a successful sync, wait while the job is running, or notify an operator when it fails.

Usage​

  1. Create an Airbyte Cloud application under Settings > Account > Applications using an identity that can read the intended workspaces and jobs.
  2. Save an Airbyte Cloud connection in the Integration Account Console.
  3. Add an Airbyte Cloud step in Workflow Studio and select the saved account under General > Connection.
  4. Choose List Connections to find a connection ID, List Jobs to inspect its sync history, or Get Job to check a specific job ID.

Inputs​

InputTypePurpose
operationstringlist_connections (default), list_jobs, or get_job.
workspaceIdUUID stringRequired workspace ID for list_connections.
connectionIdUUID stringRequired connection ID for list_jobs.
jobStatusstringOptional list_jobs filter. Values are pending, running, incomplete, failed, succeeded, and cancelled.
jobIdstringRequired positive 64-bit job ID in decimal text for get_job. Supply the ID as text to preserve every digit.
limitintegerList page size from 1 to 100. Defaults to 20.
offsetintegerList offset from 0 to 1,000,000. Defaults to 0.

Outputs​

OutputTypeMeaning
statusstringsuccess or error for the lookup.
httpStatusintegerProvider HTTP status when available.
connectionsarrayConnection summaries on the current list_connections page.
jobsarrayJob summaries on the current list_jobs page.
countintegerNumber of items on the current list page.
nextOffsetintegerNext offset when Airbyte reports another page and the offset is within bounds.
jobobjectJob summary for get_job.
errorobjectSanitized code, message, and retryable, with retryAfterSeconds when available.

A connection summary includes its connectionId, workspaceId, name, and status. A job summary includes jobId as decimal text, plus connectionId, jobType, status, and startTime. It includes lastUpdatedAt, duration, rowsSynced, and bytesSynced when Airbyte provides them. Timestamps use UTC and durations use ISO 8601. The lookup status and job status describe different events. A lookup can succeed and return a failed sync. Use the job's status when deciding whether to continue.

IntegrationAccount Requirements​

Use an authorized READY IntegrationAccount with provider AIRBYTE_CLOUD. Enter the application client ID in the protected apiKey field and the application client secret in the protected password field. The workflow credential broker resolves both fields at execution time.

Airbyte Cloud applications inherit permissions from the identity that created them. Use an identity with read access to the workspaces and connections the workflow monitors. The workspace filter limits discovery results, while the application's Airbyte permissions govern access to the resources. Airbyte Cloud authentication

Configuration​

The connector exchanges the saved application credentials for a bearer token at the fixed HTTPS Airbyte Cloud API, https://api.airbyte.com/v1. It obtains a fresh token for each execution and uses it for one read request. Put workspace, connection, and job identifiers in workflow inputs. Keep the application credentials in the saved connection.

Operations​

  • List Connections returns a page of connections from a specified workspace. Use a returned connection ID to query the associated sync jobs. Airbyte List Connections API
  • List Jobs returns a page of sync jobs for one connection. Use jobStatus to narrow the history, such as when collecting failed syncs for an operations review. Airbyte List Jobs API
  • Get Job reads one job by its numeric ID. Use the exact ID when a downstream workflow depends on a particular execution. Airbyte Get Job API

Errors and Failure Modes​

ConditionWhat to check
Invalid inputVerify the operation, UUID or job ID, status filter, and pagination bounds.
Saved connection unavailableConfirm the selected Airbyte Cloud connection is ready and has both application credentials.
HTTP 401 or 403Check whether the application is current and its identity can read the requested resources.
HTTP 404Verify the workspace, connection, or job ID and the application's access.
HTTP 429 or transient provider errorUse bounded backoff and honor the returned retry guidance when available.
Timeout or oversized responseRetry a transient timeout with bounded backoff. For a large list response, reduce the page size.

Example​

A reporting workflow receives the Airbyte job ID for an orders sync. Check the exact job before starting a warehouse transformation.

{
"operation": "get_job",
"jobId": "584217"
}

In this example, the lookup succeeds and Airbyte reports a successful sync.

{
"status": "success",
"httpStatus": 200,
"job": {
"jobId": "584217",
"connectionId": "4b12549e-3f0f-40e3-9a4a-6781b586ec07",
"jobType": "sync",
"status": "succeeded",
"startTime": "2026-11-07T05:00:00Z",
"lastUpdatedAt": "2026-11-07T05:06:48Z",
"duration": "PT6M48S",
"rowsSynced": 12500,
"bytesSynced": 824000
}
}

Let a successful sync proceed to the transformation. Give running jobs a separate branch that waits before checking again, and send lookup errors and failed syncs to distinct handling branches. If the report needs fresh data, compare the returned job timestamps with your reporting window.

Notes​

  • Pagination. Pass nextOffset back with the same filters and page size. A missing next offset marks the end of the available pages or the configured offset range. Jobs added or changed between reads can shift offset pages.
  • Rate limits. Each execution requests a token and reads one page or job. Space recurring checks and cap workflow retries. The connector surfaces retry guidance and leaves retry scheduling to the workflow.
  • API limits. The module returns selected Airbyte Cloud connection and job metadata. Self-managed Airbyte, job logs, and copied records are outside its scope.
  • Idempotency and destructive behavior. The operations read connection and job metadata. Repeated reads can return newer state. The connector cannot start, reset, or cancel a sync, or modify a connection.